heat setting in 10 seconds. You can operate
the hob. When you deactivate the hob with
the function operates again.
Power management function
Cooking zones are grouped according to the
location and number of the phases in the hob.
See the illustration.
Each phase has a maximum electricity loading of
3700 W.
The function divides the power between
cooking zones connected to the same phase.
The function activates when the total electricity
loading of the cooking zones connected to a
single phase exceeds 3700 W.
The function decreases the power to the other
cooking zones connected to the same phase.
The heat setting display of the reduced zones
changes between two levels.